Victor is the author of this solution article. Otherwise, the communication quality may be affected. Soli Wifi Datalogger Installation Instructions (For APP) Things (IOT). first report in, so please wait until the system begins to show data on. How do you connect Solis? If the connection is weak (1-2 bars) then it is recommended to install aWiFirange extender to boost the signal strength where the logger is going to be. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. AGL replaced it free of charge. Standard Warranty Document : Solis Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis Data Logger Server Information - wyjtki w firewall'u, Pylon US2000C/US3000C Battery - CAN Failure - No Battery - Deutsch, Solis Data Logger Server Information - firewall exceptions. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. If there are symbols in the password, it must be changed or the logger will not connect to it. Solis Data Logging Stick - Solis Australasia DHCP - Setting the IP Address - Solis Data Logger If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. An example of data being processed may be a unique identifier stored in a cookie. Environmental Issues, Home Automation & Internet of Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Have contacted the company who sold me it. network that uses symbols in the password. i cannot connect my solar wifi data logger to my wifi but it gets I have tried different settings with the data logger setup without having any luck. or, which is default value. did it re-connect on its own or did it need a re-boot. If you hate cookies, or are just on a diet, you can disable them altogether too. WiFi datalogger firmware is out of date Solis-(75-100)K-5G-US Solis-125K-EHV-5G Solis-(185-255)K-EHV-5G-US RHI-1P(5-10)K-HVES-5G Data Logging Stick Data Logging Box Cellular Data Logger Case Study Service and Support Download Warranty After-sales Service Monitoring PV Plant Design FAQ Enterprise Explore Newsroom Video Center Event Registration About US Company Profile You can learn more about what kind of cookies we use, why, and how from our Privacy policy. If it is not pingable and the password is good, then verify the signal strength of the WIFI Router, 3. Wi-Fi communication range: 300m in outdoor open area without obstruction. 0:00 / 1:28 Reset instruction for Solis Datalogger Solis 46.7K subscribers Subscribe 130 37K views 3 years ago When the datalogger fails, you can try to reset it to repair. No, Modified on: Tue, Oct 25, 2022 at 4:55 PM. You can select the corresponding server information according to the model of data logger used by the plant. 1. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. logger's local network which allows you to link it to the home network. Select Network, fill in the IP address assigned by the router/network administrator. I've recently installed a 6.6kW system for my home with a Solis Inverter. If the plant has multiple data loggers, please click View Plant. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Note that all scripts use Python 3. The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stickadmin page. Solis Data Loggers : Solis Note* You can use your phone, tablet or laptop. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. solis SOL-DLS-W Data Logger Wifi Stick User Guide - Manuals+ AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. We use cookies to try and give you a better experience in Freshdesk. 2.4 GHz. Connect to the inverter (to get power) 3. Start by opening yourWiFisettings and then connecting to the network that starts with "AP" - this is theWiFilogger's local network which allows you to link it to the home network. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection.Solis monitoring system can be monitored remotely by WIFI to provide users accurate and comprehensive data analysis and fault alarm at any time and place,, make product operation . A Solis 5K inverter is used here as an example. When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. I had to go up to the attic and actually point the antenna towards my router. However, there is no guarantee that interference will not occur in a particular installation. It may also be affected by lighting storms. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. In order to verify this go to Network and look at connected Inverter. If you hate cookies, or are just on a diet, you can disable them altogether too. It is highly recommended to first connect your phone to the home network that you wish to connect theWiFilogger to. I haven't been able to log onto it after many attempts. Router has a firewall blocking the data 5. Did you find it helpful? Can AGL please provide some support (a guide that is user friendly in english rather than fractured english) to help me connect and gain access to my PV data. Step 6: Plant creation succeeds. Connect to the datalogger - AP_XXXXXXXXXX, 3. You can rerun the wizard and see if that works. Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the . *, We appreciate your effort and will try to fix the article. Then plug the. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick, Solis DLS-G GPRS Datalogger setup and troubleshooting, Adding a new inverter to an existing EPM set-up, EPM 5G Plus- Abnormal Offline on Soliscloud. GitHub - hn/ginlong-solis: ESP8266 Solis to InfluxDB data logger and Issue was more to do with the router's wifi signal not being strong enough in the attic than the data logger itself. WiFi datalogger firmware is out of date. No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Solis Monitoring. Thanks for your help, my data logger looks like it is faulty. We recommend something with a larger screen. solis GPRS Stick Datalogger Instruction Manual - Manuals+ The next screen should say "Configuration Complete" and you may tap "OK (3/3)" to finish up the commissioning, The system needs betweenten and fifteen minutesto sendit'sfirst report in, so please wait until the system begins to show data onSolisCloudbefore leaving the site, Did you find it helpful? Required fields are marked *. SolisCloud - New generation Solis PV monitoring platformuk - Ginlong 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Dataloggers can be scanned or added manually by entering in the serial number. 2. Monitoring Accessory Configured But Still Won't Link? Monitoring Accessory Configured But Still Won't Link? Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Connect one end of an ethernet cable to LAN stick, 2: On the computer, click on the Network Connections and select the Local Connection. 2. Ginlong Solis is one of the world's recognised manufacturers of string solar inverters. SolisCloud is the new generation of intelligent PV system monitoring. To connect to the WIFI stick go to the WIFI connections and select the AP_XXXXXXX and connect. I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide Michael Allen Modified on: Tue, Oct 4, 2022 at 2:54 PM. Step1: Select Owner or Installer for email address registration. how to set up wifi stick in Solis inverter | Solis Data Logger Setup - YouTube 0:00 / 4:51 how to set up wifi stick in Solis inverter | Solis Data Logger Setup Infinite Laboratory. Connect wifi to the Wi-Fi stick to the interface on the inverter 2. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. A Wifi-enabled mobile phone is connected to this device parameter setting. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Did you get a response from Ginlong? You can learn more about what kind of cookies we use, why, and how from our Privacy policy. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. No-Grid - El inversor no reconoce la red. Stepl: Enter the main page of the Soliscloud APP, and click the Add plant at the bottom. my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. Users can easily check device lnformatlon by logging In the monitoring center. Step2: Enter your account and password, then click the Register. logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. 2. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. Connect the data logger to the corresponding 4-pin COM port of the inverter. If you hate cookies, or are just on a diet, you can disable them altogether too. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China.Tel: +86 (0)574 6578 1806Fax: +86 (0)574 6578 1606Email : info@ginlong.comWeb : www.ginlong.com, solis SOL-DLS-W Data Logger Wifi Stick Introduction Data Logger Wifi Stick Is mainly used: 10 inverters 10 realize, solis GPRS Stick Datalogger Delivery Content 1 GPRS stick 1 GPRS Antenna 1 Quick Installation Manual 1nstall the, BRP069B45 FTX-K (20/25/35), ATX-K (20/25/35), FTXTP-K (25/35), FTXP-K (20/25/35), ATXP-K (20/25/35), ATXTP-K (25/35) FTX-K (20/25/35), ATX-K (20/25/35), FTXTP-K, Your email address will not be published. Press the button for 5 seconds to reset2 red lights are on and off at the same time. My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. This should serve as a reminder to manually save your drafts if you wish to keep them. Tap the Plant icon in the bottom left corner of the screen, Tap the plus sign in the top right corner and then tap "Add Plant", Fill in all of the required fields on the "Create Plant" page and then tap "Done" in the top right corner, Tap "Create Plant" to finish making a system inSolisCloud- tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if theWiFidata logger is plugged into the bottom of the inverter, A scanner will automatically come up. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection. I will ask AGL for a replacement. Sorry we couldn't be helpful. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Why is my solis inverter offline? Explained by Sharing Culture SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. Or directly download from APP Store or Google Play Store by searching "SolisCloud". Solis inverter - Ginlong data logger - Neighbourhood | AGL 1. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Verify the RSSI (signal strength) is higher than 15%. Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. With solis2influx.ino one can read out all inverter data (status and statistics) via Modbus and push it to InfluxDB. Copyright@2020 Ginlong Technologies All rights reserved. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . 1: Connect LAN stick to operational inverter to provide power to LAN stick. Go to your WIFI Connections 2. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Then click Done. Shows the power supply status of the datalogger. Note: the logger is unable to connect to anyWiFinetwork that uses symbols in the password. I need a better guide to enable me to connect via an Apple Mac and PC. Connect to WIFI stick and verify firmware. We have just had a solar system installed. how to set up wifi stick in Solis inverter | Solis Data Logger Setup Insert the datalogger to the inverter COM port. This device complies with part 15 of the FCC Rules. Yes Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. cultures. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. If the WIFI stick doesn't show a connected inverter check the address of the inverter. SolisCloud Step 2: If it is a new data logger, please configure it first, then click the " Willi configure". Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! We use cookies to try and give you a better experience in Freshdesk. Ginlong Solis solar inverters Preamble. Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. Open the Local Connection Status, click. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. Solis GPRS/WiFi Data Logging Stickhi - Ginlong Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s Thanks Peter. After you connect verify the WIFI stick sees the inverter. Technician check pins 3 and 4 for 1.5 - 1.7 VDC, 2. Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as the, You should see a message that says "Bound Successfully" and now you will need to set up the logger on the local, settings and then connecting to the network that starts with "AP" - this is the.